Clack control valve error code 107
Oct 22, 2024, 14:03:03
The display shows Err – 1007, Err – 107, Err - 117, Error 107
What does error code 107 mean?
The MAV / SEPS / NHBP / AUX MAV valve motor ran too short (stalled) while searching for the correct parking position
Motorized Alternating Valve = MAV; Separate Source = SEPS; No Hard Water Bypass = NHBP; Auxiliary MAV = AUX MAV
CAUTION: Risk of injury! Only a qualified professional should carry out the following work. If the gear suddenly starts moving again, there is an acute risk of injury. If in doubt, do not hesitate to contact us beforehand.
Possible causes:
There are foreign bodies in the MAV / NHBP valve
Open the MAV/NHBP valve and check the piston and seal/stack assembly for foreign objects. Press the NEXT and REGEN buttons for 3 seconds to resynchronize the software with the piston position or disconnect power from the PC board for 5 seconds and then reconnect it.
Mechanical blockage
Check the piston and seal/stack assembly, check the reduction gears, drive interface and check that the black drive pinion of the MAV/NHBP on the motor is jammed into the motor housing. Press the NEXT and REGEN buttons for 3 seconds to re-sync the software to the piston position or unplug the power from the PC board for 5 seconds and then reconnect