Our iron filters reliably remove iron and manganese from your drinking water. In addition, your drinking water is softened and is therefore also free of limescale.

View products Calculate capacity

Subcategories (1)

Enteisenungsanlagen für Brunnenwasser (2 Products)

2 Products

PENTA Multi-Filteranlage

 (1)

Mehrzweckfilteranlage speziell für Brunnenwasser mit vollautomatischer Steuerung Clack WS 1 im Kabinettgehäuse, entfernt: Gesamt-Härte, gelöstes Eisen, gelöstes Mangan, Organik und Ammonium - für jeden Wasserverbrauch die passende Kapazität

as of €1,549.00
View product
incl. VAT excl. shipping costs
  Available

PENTA DUPLEX Multi-Filteranlage

 (3)

zweisäulige Mehrzweckfilteranlage für Brunnenwasser oder Wasser aus Eigenversorgung mit vollautomatischer Steuerung Clack WS 1 im Kabinettgehäuse, entfernt: Gesamt-Härte, gelöstes Eisen, gelöstes Mangan, Organik und Ammonium - für jeden Wasserverbrauch die passende Kapazität

as of €2,099.00
View product
incl. VAT excl. shipping costs
  Available

water de-ironing systems for well water

No more problems with rusty water

The ALFILTRA Penta multi-filter systems are ideal for well water, for example in single-family homes or for small consumers. They remove total hardness, dissolved iron, manganese, organic substances and ammonium. These fully automatic multi-filter systems, such as the Penta multi-filter system and the Penta Duplex multi-filter system, are simply installed in front of your existing water network. Equipped with an electronic, water-quantity-controlled CLACK WS1 control valve, they effectively remove iron, manganese, organic substances and ammonium using an ion exchange process and reduce water hardness. When capacity is exhausted, the system regenerates itself using the salt supply that has been filled in. A safety float valve prevents the salt container from overflowing, while the glass fiber reinforced pressure tank can withstand pressure surges of up to 16 bar.

In order to select the right system for you, it is important to know the exact water values, such as the iron content. If you do not yet have these values, we recommend a water analysis , which you can order from our shop. Find out more about water de-ironing here.

You may also be interested in

Disinfection systems
decalcification systems
Mixed bed resin
Iron & nitrate filter
Nitratfilter NO3
Deacidification plants
Kiesfilter TURBIDEX
Special filter
Zubehör für Filteranlagen

Latest Reviews

5.00
Manfred H.
Jul 24, 2023
Product: Penta Duplex 50 iron filter system
I use the system to defrost my well water, ...
I use the system to defrost my well water, which I use to refill my swimming pool. The water is crystal clear and no longer has a brown tint. The system work...
0 people found this review helpful
5.00
Robert K.
Sep 23, 2023
Product: Penta Duplex 50 iron filter system
Satisfied so far. Instead of iron-rich water, we have clear...
Satisfied so far. Instead of iron-rich water, we have clear water
0 people found this review helpful
5.00
Andreas L.
Jan 8, 2016
Product: Penta Basic 50 Eisenfilteranlage
So far, so good. Unfortunately, the steering head is damaged with the bottle...
So far, so good. Unfortunately, the control head is permanently attached to the bottle, making it impossible to change the filter material.
1 person found this review helpful
5.00
Martin H.
Apr 18, 2016
Product: FILTRASELECT-PENTA-Duplex 31 multi-filter system
A good product for anyone who has limescale problems with the water...
A good product for anyone who has limescale problems with their water and wants to get rid of them sustainably.
0 people found this review helpful
5.00
Andreas I.
Nov 15, 2019
Great performance!
1 person found this review helpful

Do you have questions?

0725 1936760
Contact form
Request a quote
Dealer registration

Product: PENTA Multi-Filteranlage

132 upvotes 1 answers
Answer:
0
For well water systems (Penta), the resin should be changed every 5 years during major maintenance.
We would be happy to make you a suitable offer.

Product: PENTA Multi-Filteranlage

114 upvotes 1 answers
Answer:
0

The resin in this filter system is designed for a pH range of 5 to 9, meaning it should work even at a pH of 6, where the water is slightly acidic.

However, you should note that although the resin can work in this pH range, slightly acidic water (pH 6) is not ideal for use as drinking water. In the long term, acidic water can cause corrosion in pipes and affect the taste of the water.

If you plan to use the filtered water as drinking water, it is recommended to also install a deacidification system. Such a system can increase the pH of the water and make it more neutral, which is not only beneficial for iron filtration but also improves the quality of drinking water and protects your plumbing.

Product: PENTA Multi-Filteranlage

90 upvotes 1 answers
Answer:
0
First the 80 μm pre-filter is installed, then the Penta system and then the carbon followed by the 20 μm sediment filter.

Product: PENTA Multi-Filteranlage

0 upvotes 1 answers
Answer:
0
Our iron removal system works on the principle of ion exchange. Iron and manganese ions in the water are replaced by sodium ions. The water flows through a special resin in the system, which binds the unwanted ions and simultaneously releases sodium ions. In this way, the iron is effectively removed from the water and the water quality is improved. After a certain amount of water has flowed through, the resin regenerates itself by rinsing with a salt solution so that it is ready for use again.

Product: PENTA Multi-Filteranlage

0 upvotes 1 answers
Answer:
0

The filter system must be frost-free as it does not have integrated frost protection. Frost damage can damage the system and impair its function. The system should therefore be installed in a heated or well-insulated area to avoid frost damage.

More questions and answers

Remove total hardness, dissolved iron, dissolved manganese, organics and ammonium with the new Penta multi-filter system for well water with…